LOVA - Large Open Vertical-Feed Air Powered
# Feed Bowl Pockets Hose Size (I.D.) Maximum Aggregate Size Air Compressor
(Recommended size at 100 psi)
Maximum Output** Common Applications
1 30 1"
(2.5cm)
1/8"
(3.5mm)
210 cfm (8AM)
300 cfm (16AM)
2 yd3/hr
(1.5 m3/hr)
fine, detailed, artistic-type work, rockscaping, patch repair.
2 21 1-1/4"
(3.2cm)
1/4"
(7mm)
315-375 cfm (8AM)
375-450 cfm (16AM)
5 yd3/hr
(3.8 m3/hr)
Refractory Spraying, low-volume repair work, smooth finish.
3 21 1-1/2"
(3.8cm)
3/8"
(10mm)
375-450 cfm (8AM)
450-600 cfm (16AM)
6 yd3/hr
(4.6 m3/hr)
Refractory Spraying, low-volume repair work, smooth finish
4 20 1-1/2"
(3.8cm)
1/2"
(13mm)
375-450 cfm (8AM)
450-600 cfm (16AM)
8 yd3/hr
(6.1 m3/hr)
Civil Construction, Higher-Volume Refractory Spraying, smooth finish
5 15 2"
(5cm)
1/2"
(13mm)
450-600 cfm (8AM)
600-750 cfm (16AM)
12 yd3/hr
(9.2 m3/hr)
Swimming Pool Construction, Civil Construction, Less Volume than L.A. (Large Aggregate) bowl
6 15L.A* 2"
(5cm)
5/8"
(16mm)
450-600 cfm (8AM)
600-750 cfm (16AM)
12 yd3/hr
(9.2 m3/hr)
Swimming Pool Construction, Conveying Aggregate for Backfill, Civil Construction
7 12 2"
(5cm)
5/8"
(16mm)
450-600 cfm (8AM)
600-750 cfm (16AM)
12 yd3/hr
(9.2 m3/hr)
Swimming Pool Construction, Less Volume than with 2-1/2" system, 15L.A. bowl provides smoother finish
*L.A. (Large Aggregate)
** feed bowl, material, air system, nozzleman capability together determine maximum output.
*** Optional electric motor drive: subtract roughly 90 SCFM (2.5M/MIN) from air requirement if electric motor used.
**** additional air may be required depending on altitude and atmospheric pressure.
REED Concrete Pumps and Guncrete Gunite Machines.
Call Us Toll-Free: 888 -779-7333
Outside US: (909) 287-2100
Fax: 909-287-2140
REED - An Independent Member of the Shea Family of Companies
13822 Oaks Avenue, Chino, CA, 91710, USA

e-mail: mike.newcomb@reedmfg.com